SXD Slip Ring Series
Explosion-Proof Slip Rings
SXD series Slip Rings are suitable to be used in potentially explosive atmospheres.
The essential requirements for safety in hazardous areas are established in European Directives 2014/34/UE of 26 February 2014. SXD is the Explosion Proof Slip Ring for your applications in zones with the presence of flammable dust.
- Specification
- FAQ
Specification
The areas exposed at explosion risk are classified according to the standard EN 60079-10, while the technical requirements of the electrical systems in the classified areas are given by EN 60079-31 standard. Technical protection for the electrical equipment according to the IEC standards 60079-0 and IEC 60079-1.
SXD II 2D Ex tb IIIC IP65 T 80°C
- System type: group II surface system
- Category: 2D elevate protection, zone 21 and zone 22 use areas with presence of inflammable dusts
- Type of protection mode: Ex tb - dustproof
- Type of dust: IIIC - conductive dusts
- Protection Degree: IP65
- Temperature class: T 80 °C, defines the maximum temperature of the surface.
GENERAL CHARACTERISTICS
- Models: SXD35, 50, 70, 91 available in blind or through hole version (SXD35 only blind)
- Poles function: power up to 40 A, signals and data transmission
- Max. voltage: 400 V AC – 160 V DC
- Max current: 40 A
- Protection degree: IP 65
- Max RPM: 150 rpm
- Mounting position: Vertical / Horizontal
- Working temp.: - 20 °C / + 40 °C
- Relative humidity: 30% to 60%